Takfly Fiber Optic 120km DWDM XFP Fiber Optical Transceiver

Product Details
Customization: Available
Type: Fiber Transceiver
Wiring Devices: Takfly 120km DWDM XFP Optical Transceiver
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Type of Ownership
Limited Company
OEM/ODM Availability
Yes
  • Takfly Fiber Optic 120km DWDM XFP Fiber Optical Transceiver
  • Takfly Fiber Optic 120km DWDM XFP Fiber Optical Transceiver
  • Takfly Fiber Optic 120km DWDM XFP Fiber Optical Transceiver
  • Takfly Fiber Optic 120km DWDM XFP Fiber Optical Transceiver
  • Takfly Fiber Optic 120km DWDM XFP Fiber Optical Transceiver
  • Takfly Fiber Optic 120km DWDM XFP Fiber Optical Transceiver
Find Similar Products

Basic Info.

Model NO.
XFP Optical Transceiver
Condition
New
Fiber Mode
Single-Mode
Connector
LC
Delivery Time
Within 5 to 7 Days
Sample Order
Available
Export Market
Global
Transport Package
Customized
Specification
Customized
Trademark
Takfly
Origin
Shenzhen, China
HS Code
8542900000
Production Capacity
1000/Week

Product Description

Takfly Fiber Optic 120km DWDM XFP Fiber Optical Transceiver
Takfly Fiber Optic 120km DWDM XFP Fiber Optical Transceiver
Takfly Fiber Optic 120km DWDM XFP Fiber Optical Transceiver
Takfly Fiber Optic 120km DWDM XFP Fiber Optical Transceiver
Takfly Fiber Optic 120km DWDM XFP Fiber Optical Transceiver

Fiber Optic Transceiver Features
Wavelength selectable to C-band ITU-T grid wavelengths            
Suitable for use in 100GHz channel spacing DWDM systems XFP MSA Rev 4.5 Compliant
Data rate from 9.95Gbps to 11.3Gbps
Cooled EML and APD receiver link length up to 120km (with amplifier)
Low Power Dissipation 3.5W MaximumXFI and lineside loopback Mode
Supported-5ºC to 70ºC Operating Case Temperature
Diagnostic Performance Monitoring of module temperature, Supply Voltages, laser bias current, transmit optical power, and receive optical power RoHS compliant (lead free) 

Fiber Optic Transceiver Applications
SONET OC-192&SDH STM 64
Ethernet (10GBASE and 10GBASE with FEC)DWDM
Networks  
 
Fiber Optic Transceiver Description
Takfly 120km XFP Transceiver exhibits excellent wavelength stability, supporting operation at 100 GHz channel, cost effective module. It is designed for 10G SDH/SONET and 10G Ethernet applications.
The transmitter section incorporates a colded EML laser, and the receiver section consists of a APD photodiode integrated with a TIA, Integrated low power dual CDR with Electronic Dispersion Compensation(EDC).
This module can be used to compensate channel impairments caused by either single mode fiber up to 120 km .All modules satisfy class I laser safety requirements. Takfly XFP transceiver provides an enhanced monitoring interface, which allows real-time access to device operating parameters such as transceiver temperature, laser bias current, transmitted optical power, received optical power and transceiver supply voltage.
   
Fiber Optic Transceiver Operating Conditions
Parameter Symbol Min Typical Max Unit
Supply Voltage 1 Vcc3 3.13 3.3 3.47 V
Supply current 1 Icc3 - - 750 mA
Supply Voltage 2 Vcc5 4.75 5 5.25 V
Supply current 2 Icc5 - - 500 mA
Supply Voltage 3 Vcc2 1.71 1.8 1.89 V
Supply current 3 Icc2 - - 750 mA
Operating Case temperature Tca -5 - 70 ºC
Module Power Dissipation Pm - - 3.5 W
 
Fiber Optic Transceiver Transmitter Specifications - Optical
Parameter Symbol Min Typical Max Unit
Center Wavelength-Start of Life [1] lc lc -25 lc lc +25 pm
Center Wavelength-End of life [1] lc lc -100 lc lc+100 pm
Optical Transmit Power Po -2 - +2 dBm
Optical Transmit Power (disabled) PTX_DIS - - -30 dBm
Extinction Ratio ER 9 - - dB
Jitter Generation(P-P) JG P-P - - 0.1 UI
Jitter Generation(RMS) JG RMS - - 0.01 UI
Spectral Width (-20dB) Δλ20 -   0.3 nm
Side Mode Suppression Ratio SMSR 30 - - dB
Dispersion penalty(2400ps/nm) [2] DP - - 2 dB
Relative Intensity Noise RIN - - -130 dB/Hz
Eye Mask Compliant with ITU-T G.691 STM-64 eye mask
Note:
Wavelength stability is achieved within 60 seconds (max) of power up. BER=10^-12; PRBS 2^[email protected]
  
Fiber Optic Transceiver Transmitter Specifications - Electrical
Parameter Symbol Min Typical Max Unit
Input differential impedance Rim - 100 - Ω
Differential data Input VtxDIFF 120 - 850 mV
Transmit Disable Voltage VD 2.0 - Vcc3+0.3 V
Transmit Enable Voltage Ven 0 - +0.8 V
Transmit Disable Assert Time Vn - - 10 us

Fiber Optic Transceiver Receiver Specifications - Optical
Parameter Symbol Min Typical Max Unit
Maximum Input Power RX-overload -7 - - dBm
Input Operating Wavelength λ 1528 - 1565 nm
Reflectance Rrx - - -27 dB
Loss of Signal Asserted LOS_A -34 - - dBm
LOS De-Asserted LOS_D - - -24 dBm
LOS Hysteresis LOS_H 0.5 - - dB
Receiver Sensitivity
Data rate (Gb/s) BER Dispersion (ps/nm) Sensitivity back-to-back at OSNR>30dB (dBm) Power Penalty at OSNR>30dB (dB)
9.95 ~10.7 1e-12 -500 to 2400 -24 2
11.1 ~11.3 1e-12 -500 to 2400 -23 2
OSNR Performance
Data rate (Gb/s) BER Dispersion (ps/nm) Min OSNR Back-to-back at Power: -7 to -18dBm (dB) Max OSNR Penalty at Power:-7 to -18dBm (dB)
9.95 ~10.7 1e-12 -500 to 2400 24 4
11.1 ~11.3 1e-4 -500 to 2400 16 4
                 
Note:
1. BER=10^-12; PRBS 2^31-1;

Fiber Optic Transceiver Receiver Specifications - Electrical
Parameter Symbol Min Typical Max Unit
Output differential impedance Rom - 100 -- Ω
Differential Output Swing Vout P-P 350 - 850 mV
Rise/Fall Time [1] Tr / Tf 24 - - ps
Loss of Signal -Asserted VOH 2 - Vcc3+0.3- V
Loss of Signal -Negated VOL GND - GND+0.5 V
Note:
20%-80%;

Fiber Optic Transceiver Reference Clock
Parameter Symbol Min Typical Max Unit
Clock Differential Input Impedance CI 80 100 120 Ω
Differential Input Amplitude (p-p) DCA 640- - 1600 mV
Reference Clock Duty Cycle RCY 40 - 60 %
Reference Clock Rise/Fall Time [1] Tr/Tf 200 - 1250 ps
Reference Clock Frequency fu - Baud/64 - MHz
Note:
20%-80%;
 
Fiber Optic Transceiver C-band λc Wavelength Guide
ITU Channel
Product Code
Frequency(THz) Wavelength ITU Channel
Product Code
Frequency(THz) Wavelength
17 191.7 1563.86 40 194.0 1545.32
18 191.8 1563.05 41 194.1 1544.53
19 191.9 1562.23 42 194.2 1543.73
20 192.0 1561.42 43 194.3 1542.94
21 192.1 1560.61 44 194.4 1542.14
22 192.2 1559.79 45 194.5 1541.35
23 192.3 1558.98 46 194.6 1540.56
24 192.4 1558.17 47 194.7 1539.77
25 192.5 1557.36 48 194.8 1538.98
26 192.6 1556.55 49 194.9 1538.19
27 192.7 1555.75 50 195.0 1537.40
28 192.8 1554.94 51 195.1 1536.61
29 192.9 1554.13 52 195.2 1535.82
30 193.0 1553.33 53 195.3 1535.04
31 193.1 1552.52 54 195.4 1534.25
32 193.2 1551.72 55 195.5 1533.47
33 193.3 1550.92 56 195.6 1532.68
34 193.4 1550.12 57 195.7 1531.90
35 193.5 1549.32 58 195.8 1531.12
36 193.6 1548.51 59 195.9 1530.33
37 193.7 1547.72 60 196.0 1529.55
38 193.8 1546.92 61 196.1 1528.77
39 193.9 1546.12    
 


Fiber Optic Transceiver Pin Descriptions
Pin Logic Symbol Name/Description Ref.
1   GND Module Ground 1
2   VEE5 Optional -5.2 Power Supply - Not required  
3 LVTTL-I Mod-Desel Module De-select; When held low allows the module to  , respond to 2-wire serial interface commands  
4 LVTTL-O Interrupt Interrupt (bar); Indicates presence of an important condition which can be read over the serial 2-wire interface 2
5 LVTTL-I TX_DIS Transmitter Disable; Transmitter laser source turned off  
6   VCC5 +5 Power Supply  
7   GND Module Ground 1
8   VCC3 +3.3V Power Supply  
9   VCC3 +3.3V Power Supply  
10 LVTTL-I SCL Serial 2-wire interface clock 2
11 LVTTL-  I/O SDA Serial 2-wire interface data line 2
12 LVTTL-O Mod_Abs Module Absent; Indicates module is not present. Grounded in the module. 2
13 LVTTL-O Mod_NR Module Not Ready; 2
14 LVTTL-O RX_LOS Receiver Loss of Signal indicator 2
15   GND Module Ground 1
16   GND Module Ground 1
17 CML-O RD- Receiver inverted data output  
18 CML-O RD+ Receiver non-inverted data output  
19   GND Module Ground 1
20   VCC2 +1.8V Power Supply  
21 LVTTL-I P_Down/RST Power Down; When high, places the module in the low power stand-by mode and on the falling edge of P_Down initiates a module reset  
Reset; The falling edge initiates a complete reset of the module including the 2-wire serial interface, equivalent to a power cycle.  
22   VCC2 +1.8V Power Supply  
23   GND Module Ground 1
24 PECL-I RefCLK+ Reference Clock non-inverted input, AC coupled on the host board 3
25 PECL-I RefCLK- Reference Clock inverted input, AC coupled on the host board   3
26   GND Module Ground 1
27   GND Module Ground 1
28 CML-I TD- Transmitter inverted data input  
29 CML-I TD+ Transmitter non-inverted data input  
30   GND Module Ground 1
Notes:
1. Module circuit ground is isolated from module chassis ground within the module.
2. Open collector; should be pulled up with 4.7k - 10k ohms on host board to a voltage between 3.15Vand 3.6V.