Gold Member Since 2013
Audited Supplier
Takfly Communications Co., Ltd.

Unmanaged Poe Switch, 100Mbps Poe Switch, 8 RJ45 Ports Poe Switch manufacturer / supplier in China, offering 8 RJ45 Ports+1 Fiber Uplink Port 100Mbps Unmanaged Poe Switch, 600 Times Long Life MPO MTP Fiber Cleaner, 12 Core Waterproof Sc APC Fiber Optic Pigtail and so on.

(/ )

Supplier Homepage Product Fiber optic active product POE switch 8 RJ45 Ports+1 Fiber Uplink Port 100Mbps Unmanaged Poe Switch

8 RJ45 Ports+1 Fiber Uplink Port 100Mbps Unmanaged Poe Switch

FOB Price: US $1-72.6 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $1-72.6/ Piece
Get Latest Price
Port: Shenzhen, China
Production Capacity: 50000pieces/Month
Payment Terms: L/C, T/T, Western Union, Paypal

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.:   DF-155M-8P-F
  • Type: Ethernet Switch
  • Ports: 9
  • Weight: 612g
  • Item Name: 9 Ports Ethernet Swith Poe/Poe Switch
  • Business Type: Manufacturer & Trading
  • Working Temperature: 0ºC~55ºC
  • Power Consumption: The Device <5W
  • Transport Package: Standard Carton Packing or Customer Required
  • Origin: Shenzhen China
  • Communication Mode: Full-Duplex & Half-Duplex
  • Transmission Rate: 100Mbps
  • Slot: 9
  • Certification: RoHS, Ce, ISO9001, CCC, SGS
  • Color: Black
  • Mean Time Between Failures: More Than 50000h
  • Voltage Range: DC48~56V
  • Trademark: TAKFLY/OEM
  • Specification: 188.5mmx102.5mmx28.25mm
  • HS Code: 8504401400
Product Description

 DF-155M-8P-F     100m  100Mbps  8 RJ45+1 fiber uplink Ports unmanaged Poe Switch/POE Product Description

1.Overviews

DF-155M-8P-F is specialized unmanaged POE switch designed for video surveillance and network project system, etc. It provides 8 x 100Mbps Ethernet ports and 1 x 100Mbps fiber optical port, support VLAN function, can effectively prevent whole system from broadcast storm so that make the data transfer more safe.

This POE network switch can meet customer's general demands. POE network switch with POE function, designed for high-definition network camera's internet access. It provides 8 100Mbps PoE Ethernet switches, complies with IEEE802.3af/at standards, and also simplifies wiring, avoids the troublesome of installing power socket for powered devices.

2.Features

1.Provide 8 x 100Mbps Ethernet ports, 1 x 100Mbps fiber optical port
2.Support End-Span method, complies with IEEE802.3 af/at standards, can supply max 30W power which is possible to power high-power infrared cameras.
3.Comply with IEEE802.3, IEEE802.3u, IEEE802.3af/at standards.
4.Support IEEE802.3x full-duplex flow control, support Auto MDI/MDIX
5.Support port-base Vlan, prevent from broadcast storm so that make data conversion more efficient and safe.
6.Various LED display functions can real-timely display the device's current working conditions, and help prompt facility and remove trouble easily.
7.Excellent lightning protection, lightning capacity up to 2KV
8.Easy to install and operate on walls or on the desktops
 
3.Technical Specifications
ItemDescription
ModelDF-155M-8P-F
Power SupplyPower Supply Mode Power Adaptor
Voltage RangeDC 48~56V
Power ConsumptionThe device <5W,                                    POE power supply <120W
Network Port ParameterNetwork Ports1~8 Ethernet Port:10/100Mbps
1 Uplink optical fiber port:SC/FC/ST 
Transmission Distance1~8 Ethernet Port:0~100m
Mandatory 10 Mbps reach up to 250m
Uplink optical fiber port:single mode fiber 20km
Transmission Media1~8 Ethernet Port:Cat5e/6 standard UTP cable, Uplink optical Port:optical fiber
POE AgreementIEEE802.3 af/at standards
PoE Power Supply ModeEnd-span method
PoE Power Supply WattageEach port≤30W,Whole device<120W
Network Switch SpecificationNetwork StandardIEEE 802.3/802.3u
Swap ModeStore-and- forward
Data-Caching Mechanism1M
MAC Address List2K
Status IndicatorsPower Indicator LightOne power light (Green)
Optical Fiber Port IndicatorOne fiber link indication light ( green), Green light keeps on when the fiber port is well connected; Blinking when transceiver data
FE Uplink PortLED (Green): On, port is link on; Off, port is link down;
PoE Indicator8 PoE indicator light(yellow)
PoE Network Port LED1~8 port ( green light on RJ45 jack) Keeps on when normally connected, Blinking when transceiver data
Switch Vlan SwitchOn: CCTV Mode, support 250meter power and data
Off: normal mode, support 100meter
Protection LevelSurge ImmunityLevel 3, executive standard:IEC61000-4-5
Electrostatic Protection1a touch electric discharge: level 3             1a Air discharge: level 3                   Executive standard:IEC61000-4-2
Operating EnvironmentWorking Temperature0ºC~55ºC
Storage Temperature-40ºC~70ºC
Humidity(non-congeal)0~95%
Mechanical AttributesDimensions (L*W*H)188.5mmx102.5mmx28.25mm
ColorBlack
Weight612g
ReliabilityMean time between failures (MTBF)>50000h
 
Note:If any changes with product specification, forgive without prior notice.
1) As transmission distance has certain relation with the cable, so you are suggested to use standard cat5e/6 cable for longest distance needed.

4.V-lan

4.1 Introduction
    When V-lan function is opened, the LAN port can't make data conversion but can only communicate via uplink port. The V-LAN workstation is built separately between every network port and UP-LINK port.
In the same V-lan workstation, no matter which actual PoE switch being connected, the signal transmission are separately isolated from each other which seems they are on the different switches. The broadcast in the same V-lan can only be received by the members but can't be transmitted into other V-lan, which can greatly control unnecessary broadcast storm. What's more, different V-lan can't even communicate with each other when there is no routing, which increases the safe degree among different department in the enterprise.

4.2 Configuration
   Toggle the V-lan button on the back of the switch to ON state, V-lan indicator lights, then press the reset button to restart the switch, in this way V-lan functions.
Note:
   Please press reset button or repower the device when turn on V-lan, only in this way the switch can enter corresponding mode.

5.Installation

Packing List
Before installation, please check the following equipment and accessories, if there are any missing, please contact with your supplier.
1) 1 set of DF-155M-8P-F
2) 1 power adapter
3) 1 user manual
      warranty card
 
Please install as below steps:
1.Before installation, please turn off the power of all signal sources and the monitor in case of the damage to transmission device
2.Using network cables to connect with Ethernet ports of IP cameras and POE ports of PSE-2 series unmanaged POE switch
3.Using UP-LINK port to connect NVR or computer etc. Device.
4.Check weather installation is correct and the device undamaged. Before power on PSE-2 series unmanaged POE switch, make sure that all connections are reliable
5.Confirm all network devices are powered and can work normally.

6.Troubleshooting

When the device encountered with troubles, it can be solved by the methods below:
1) Make sure the device is installed correctly referring to the requirements;
2) Make sure RJ45 cable is good contacted without open circuit; the cable design complies with EIA/TIA568A or 568B international standards.
3) Each PoE port can provides max 30W to switch and the total power is less than the maximum power provided by the device. So please don't connect with the PoE device which is more than 30W.
4) Press reset button to check if the device can work properly.
5) Replace the trouble device with a normal working device to check if the device is damaged.
6) If all the above methods still don't work, please contact with manufacturer directly.

7.Making methods of RJ45 connector

Required tools: wire crimpers, network cable tester.
The wire sequence of RJ45l connector must complies with international standard of EIA/TIA 568A or EIA/TIA 568B.
Strip about 2cm's of insulating jacket to let 4 pairs UTP can be seen.
Separate 4 pairs UTP cable, and try to straighten each pair.
Arrange 8 cables with correct line sequence of EIA/TIA 568A or EIA/TIA 568B.
Cut thread residue and leave 1.5cm wire which exposed outside the insulating layer, and ensure 8 wires are straight and neat.
Put 8 wires in RJ 45 connector, then press with wire crimpers.
Repeat above five steps , make the other side of UTP cable; Then using the cable tester to test whether the cat5e/6 works normally.
 
 
 
Send your message to this supplier
Avatar
Ms. Sophie
*From:
To: Ms. Sophie
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category